The CLEO-III ring imaging Cherenkov detector

R. J. Mountain, Marina Artuso, R. Ayad, F. Azfar, A. Efimov, S. Kopp, G. Majumder, S. Schuh, Tomasz Skwarnicki, Sheldon Stone, G. Viehhauser, J. C. Wang, S. Anderson, A. Smith, Y. Kubota, E. Lipeles, T. Coan, J. Staeck, V. Fadeyev, I. VolobouevJ. Ye

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

The CLEO-III detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.

Original languageEnglish (US)
Pages (from-to)77-86
Number of pages10
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume433
Issue number1-2
DOIs
StatePublished - Aug 21 1999

Fingerprint

photosensors
Detectors
Imaging techniques
rings
detectors
Radiators
radiators
Charged particles
low noise
readout
charged particles
Electronic equipment
Photons
chambers
wire
Wire
Crystals
photons
electronics
crystals

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

The CLEO-III ring imaging Cherenkov detector. / Mountain, R. J.; Artuso, Marina; Ayad, R.; Azfar, F.; Efimov, A.; Kopp, S.; Majumder, G.; Schuh, S.; Skwarnicki, Tomasz; Stone, Sheldon; Viehhauser, G.; Wang, J. C.; Anderson, S.; Smith, A.; Kubota, Y.; Lipeles, E.; Coan, T.; Staeck, J.; Fadeyev, V.; Volobouev, I.; Ye, J.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 433, No. 1-2, 21.08.1999, p. 77-86.

Research output: Contribution to journalArticle

Mountain, RJ, Artuso, M, Ayad, R, Azfar, F, Efimov, A, Kopp, S, Majumder, G, Schuh, S, Skwarnicki, T, Stone, S, Viehhauser, G, Wang, JC, Anderson, S, Smith, A, Kubota, Y, Lipeles, E, Coan, T, Staeck, J, Fadeyev, V, Volobouev, I & Ye, J 1999, 'The CLEO-III ring imaging Cherenkov detector', Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 433, no. 1-2, pp. 77-86. https://doi.org/10.1016/S0168-9002(99)00466-0
Mountain, R. J. ; Artuso, Marina ; Ayad, R. ; Azfar, F. ; Efimov, A. ; Kopp, S. ; Majumder, G. ; Schuh, S. ; Skwarnicki, Tomasz ; Stone, Sheldon ; Viehhauser, G. ; Wang, J. C. ; Anderson, S. ; Smith, A. ; Kubota, Y. ; Lipeles, E. ; Coan, T. ; Staeck, J. ; Fadeyev, V. ; Volobouev, I. ; Ye, J. / The CLEO-III ring imaging Cherenkov detector. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1999 ; Vol. 433, No. 1-2. pp. 77-86.
@article{1161ba86bdbf441ca2d125c1c1dcbb28,
title = "The CLEO-III ring imaging Cherenkov detector",
abstract = "The CLEO-III detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.",
author = "Mountain, {R. J.} and Marina Artuso and R. Ayad and F. Azfar and A. Efimov and S. Kopp and G. Majumder and S. Schuh and Tomasz Skwarnicki and Sheldon Stone and G. Viehhauser and Wang, {J. C.} and S. Anderson and A. Smith and Y. Kubota and E. Lipeles and T. Coan and J. Staeck and V. Fadeyev and I. Volobouev and J. Ye",
year = "1999",
month = "8",
day = "21",
doi = "10.1016/S0168-9002(99)00466-0",
language = "English (US)",
volume = "433",
pages = "77--86",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - The CLEO-III ring imaging Cherenkov detector

AU - Mountain, R. J.

AU - Artuso, Marina

AU - Ayad, R.

AU - Azfar, F.

AU - Efimov, A.

AU - Kopp, S.

AU - Majumder, G.

AU - Schuh, S.

AU - Skwarnicki, Tomasz

AU - Stone, Sheldon

AU - Viehhauser, G.

AU - Wang, J. C.

AU - Anderson, S.

AU - Smith, A.

AU - Kubota, Y.

AU - Lipeles, E.

AU - Coan, T.

AU - Staeck, J.

AU - Fadeyev, V.

AU - Volobouev, I.

AU - Ye, J.

PY - 1999/8/21

Y1 - 1999/8/21

N2 - The CLEO-III detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.

AB - The CLEO-III detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.

UR - http://www.scopus.com/inward/record.url?scp=0032629285&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032629285&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(99)00466-0

DO - 10.1016/S0168-9002(99)00466-0

M3 - Article

AN - SCOPUS:0032629285

VL - 433

SP - 77

EP - 86

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 1-2

ER -