Iterative deformable FEM model for nonrigid PET/MRI breast image coregistration

Mehmet Z. Unlu, Andrzej Krol, Alphonso Magri, David H. Feiglin, James A. Mandel, Edward D. Lipson, Ioana L. Coman, Wei Lee, Gwen Tillapaugh-Fay

Research output: Chapter in Book/Entry/PoemConference contribution

1 Scopus citations

Abstract

We implemented an iterative nonrigid registration algorithm to accurately combine functional (PET) and anatomical (MRI) images in 3D. Our method relies on a Finite Element Method (FEM) and a set of fiducial skin markers (FSM) placed on breast surface. The method is applicable if the stress conditions in the imaged breast are virtually the same in PET and MRI. In the first phase, the displacement vectors of the corresponding FSM observed in MRI and PET are determined, then FEM is used to distribute FSM displacements linearly over the entire breast volume. Our FEM model relies on the analogy between each of the orthogonal components of displacement field, and the temperature distribution field in a steady state heat transfer (SSHT) in solids. The problem can thus be solved via standard heat-conduction FEM software, with arbitrary conductivity of surface elements set much higher than that of volume elements. After determining the displacements at all mesh nodes, moving (MRI) breast volume is registered to target (PET) breast volume using an image-warping algorithm. In the second iteration, to correct for any residual surface and volume misregistration, a refinement process is applied to the moving image, which was already grossly aligned with the target image in 3D using FSM. To perform this process we determine a number of corresponding points on each moving and target image surfaces using a nearest-point approach. Then, after estimating the displacement vectors between the corresponding points on the surfaces we apply our SSHT model again. We tested our model on twelve patients with suspicious breast lesions. By using lesions visible in both PET and MRI, we established that the target registration error is below two PET voxels. The surface registration error is comparable to the spatial resolution of PET.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2006
Subtitle of host publicationImage Processing
DOIs
StatePublished - 2006
EventMedical Imaging 2006: Image Processing - San Diego, CA, United States
Duration: Feb 13 2006Feb 16 2006

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6144 II
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2006: Image Processing
Country/TerritoryUnited States
CitySan Diego, CA
Period2/13/062/16/06

Keywords

  • Deformable model
  • Fiducial skin markers
  • Finite element method
  • MRI/PET breast image registration
  • Multimodal
  • Nonrigid image registration
  • Warping

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging
  • Biomaterials

Fingerprint

Dive into the research topics of 'Iterative deformable FEM model for nonrigid PET/MRI breast image coregistration'. Together they form a unique fingerprint.

Cite this