N2 - OBJECTIVE:: The goal of the study was to evaluate the effectiveness of tympanometry and wideband reflectance (WBR) in detecting conductive hearing loss (CHL) in young infants. METHODS:: Type of hearing loss was determined using auditory brainstem response using air- and bone-conducted tone bursts in 84 ears from 70 infants (median age = 10 weeks). Of these 84 ears, 60 are included in the current analysis: 43 with normal hearing (NH) and 17 with CHL. Tympanometry was measured using probe tone frequencies of 226, 678, and 1000 Hz. Tympanograms were evaluated in two ways: (1) Acoustic middle ear admittance (Ya, in millimhos); and (2) two-category classification (normal/abnormal), as described by Baldwin (2006). Measures of Ya were evaluated in two ways: by admittance-magnitude tympanograms and calculated admittance magnitude from subcomponents (conductance and susceptance). WBR was measured in response to a chirp stimulus after probe calibration. WBR was analyzed into thirteen 1/3 octave bands. Tests for statistical differences for two-category classification were analyzed using Chi-squared and Ya, and WBR were analyzed using repeated-measures analyses of variances. Cohen's d and likelihood ratios were computed for comparison with statistically significant differences. RESULTS:: Ya measured with 678- and 1000 Hz probe tones was significantly different between ears with CHL and NH. Two-category classification of tympanograms using a 1000 Hz probe tone was significantly different between ears with CHL and NH. Neither two-category classification nor Ya was significantly different between ears identified with CHL and NH using a 226 Hz probe tone. WBR was significantly higher in the frequency bands 800 to 2500 Hz and in the frequency band centered at 6300 Hz in infants with CHL. Effect sizes (Cohen's d) were greater than 2 for several WBR frequency bands and Ya measured with 1000 Hz probe tones. The results were similar for calculations of Ya from admittance-magnitude and subcomponent tympanograms. Positive likelihood ratios for WBR ranged between 8.1 and 38, and those for Ya using 1000 Hz ranged between 12.5 and 32. CONCLUSIONS:: CHL in young infants can be detected well with WBR or tympanometry using probe frequencies of 678 and 1000 Hz.
AB - OBJECTIVE:: The goal of the study was to evaluate the effectiveness of tympanometry and wideband reflectance (WBR) in detecting conductive hearing loss (CHL) in young infants. METHODS:: Type of hearing loss was determined using auditory brainstem response using air- and bone-conducted tone bursts in 84 ears from 70 infants (median age = 10 weeks). Of these 84 ears, 60 are included in the current analysis: 43 with normal hearing (NH) and 17 with CHL. Tympanometry was measured using probe tone frequencies of 226, 678, and 1000 Hz. Tympanograms were evaluated in two ways: (1) Acoustic middle ear admittance (Ya, in millimhos); and (2) two-category classification (normal/abnormal), as described by Baldwin (2006). Measures of Ya were evaluated in two ways: by admittance-magnitude tympanograms and calculated admittance magnitude from subcomponents (conductance and susceptance). WBR was measured in response to a chirp stimulus after probe calibration. WBR was analyzed into thirteen 1/3 octave bands. Tests for statistical differences for two-category classification were analyzed using Chi-squared and Ya, and WBR were analyzed using repeated-measures analyses of variances. Cohen's d and likelihood ratios were computed for comparison with statistically significant differences. RESULTS:: Ya measured with 678- and 1000 Hz probe tones was significantly different between ears with CHL and NH. Two-category classification of tympanograms using a 1000 Hz probe tone was significantly different between ears with CHL and NH. Neither two-category classification nor Ya was significantly different between ears identified with CHL and NH using a 226 Hz probe tone. WBR was significantly higher in the frequency bands 800 to 2500 Hz and in the frequency band centered at 6300 Hz in infants with CHL. Effect sizes (Cohen's d) were greater than 2 for several WBR frequency bands and Ya measured with 1000 Hz probe tones. The results were similar for calculations of Ya from admittance-magnitude and subcomponent tympanograms. Positive likelihood ratios for WBR ranged between 8.1 and 38, and those for Ya using 1000 Hz ranged between 12.5 and 32. CONCLUSIONS:: CHL in young infants can be detected well with WBR or tympanometry using probe frequencies of 678 and 1000 Hz.
UR - http://www.scopus.com/inward/record.url?scp=84875218314&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875218314&partnerID=8YFLogxK
U2 - 10.1097/AUD.0b013e31826fe611
DO - 10.1097/AUD.0b013e31826fe611
M3 - Article
C2 - 23263407
AN - SCOPUS:84875218314
SN - 0196-0202
VL - 34
SP - 168
EP - 178
JO - Ear and hearing
JF - Ear and hearing
IS - 2
ER -