TY - GEN
T1 - Evaluation of excess inductance and capacitance of microstrip discontinuities
AU - Sarkar, Tapan K.
AU - Maricevic, Zoran A.
AU - Zhang, J. B.
AU - Djordjevic, Antonije R.
N1 - Publisher Copyright:
© 1992 IEEE.
PY - 1992
Y1 - 1992
N2 - This paper presents a technique for evaluation of excess inductance and capacitance of certain transmission line discontinuities (bends, mitered bends, impedance steps, tees and simple vias).This technique is fairly general and can treat any arbitrary shaped transmission line structure, assumed to be consisting of perfectly conducting foils located above a perfectly conducting ground plane, embedded in various dielectric la+yers. An estimate of the error bound is given.
AB - This paper presents a technique for evaluation of excess inductance and capacitance of certain transmission line discontinuities (bends, mitered bends, impedance steps, tees and simple vias).This technique is fairly general and can treat any arbitrary shaped transmission line structure, assumed to be consisting of perfectly conducting foils located above a perfectly conducting ground plane, embedded in various dielectric la+yers. An estimate of the error bound is given.
UR - http://www.scopus.com/inward/record.url?scp=84939030638&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84939030638&partnerID=8YFLogxK
U2 - 10.1109/EPEP.1992.572278
DO - 10.1109/EPEP.1992.572278
M3 - Conference contribution
AN - SCOPUS:84939030638
T3 - Electrical Performance of Electronic Packaging, EPEP 1992
SP - 104
EP - 106
BT - Electrical Performance of Electronic Packaging, EPEP 1992
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 1992 Electrical Performance of Electronic Packaging, EPEP 1992
Y2 - 22 April 1992 through 24 April 1992
ER -