Abstract
Closed-form expressions for the approximation of frequency variations of per-unit-length resistance and inductance of microstrip transmission lines are presented. The provided expressions guarantee causality of the time-domain response. They are valid from dc up to the highest frequencies for which the quasi-static analysis of microstrip transmission lines is applicable. Additionally, the expressions take into account the finite width of the ground plane and can deal with a broad range of dimensions of microstrip lines. The correctness of the formulas is experimentally verified.
Original language | English (US) |
---|---|
Article number | 6835197 |
Pages (from-to) | 1604-1612 |
Number of pages | 9 |
Journal | IEEE Transactions on Electromagnetic Compatibility |
Volume | 56 |
Issue number | 6 |
DOIs | |
State | Published - Dec 1 2014 |
Keywords
- Causality
- microstrip lines
- signal integrity (SI)
- transmission lines
ASJC Scopus subject areas
- Atomic and Molecular Physics, and Optics
- Condensed Matter Physics
- Electrical and Electronic Engineering