TY - JOUR
T1 - A comparison of fibre-optic distributed temperature sensing to traditional methods of evaluating groundwater inflow to streams
AU - Briggs, Martin A.
AU - Lautz, Laura K.
AU - Mckenzie, Jeffrey M.
PY - 2012/4/30
Y1 - 2012/4/30
N2 - There are several methods for determining the spatial distribution and magnitude of groundwater inputs to streams. We compared the results of conventional methods [dye dilution gauging, acoustic Doppler velocimeter (ADV) differential gauging, and geochemical end-member mixing] to distributed temperature sensing (DTS) using a fibre-optic cable installed along 900 m of Ninemile Creek in Syracuse, New York, USA, during low-flow conditions (discharge of 1·4 m 3 s -1). With the exception of differential gauging, all methods identified a focused, contaminated groundwater inflow and produced similar groundwater discharge estimates for that point, with a mean of 66·8 l s -1 between all methods although the precision of these estimates varied. ADV discharge measurement accuracy was reduced by non-ideal conditions and failed to identify, much less quantify, the modest groundwater input, which was only 5% of total stream flow. These results indicate ambient tracers, such as heat and geochemical mixing, can yield spatially and quantitatively refined estimates of relatively modest groundwater inflow even in large rivers. DTS heat tracing, in particular, provided the finest spatial characterization of groundwater inflow, and may be more universally applicable than geochemical methods, for which a distinct and consistent groundwater end member may be more difficult to identify.
AB - There are several methods for determining the spatial distribution and magnitude of groundwater inputs to streams. We compared the results of conventional methods [dye dilution gauging, acoustic Doppler velocimeter (ADV) differential gauging, and geochemical end-member mixing] to distributed temperature sensing (DTS) using a fibre-optic cable installed along 900 m of Ninemile Creek in Syracuse, New York, USA, during low-flow conditions (discharge of 1·4 m 3 s -1). With the exception of differential gauging, all methods identified a focused, contaminated groundwater inflow and produced similar groundwater discharge estimates for that point, with a mean of 66·8 l s -1 between all methods although the precision of these estimates varied. ADV discharge measurement accuracy was reduced by non-ideal conditions and failed to identify, much less quantify, the modest groundwater input, which was only 5% of total stream flow. These results indicate ambient tracers, such as heat and geochemical mixing, can yield spatially and quantitatively refined estimates of relatively modest groundwater inflow even in large rivers. DTS heat tracing, in particular, provided the finest spatial characterization of groundwater inflow, and may be more universally applicable than geochemical methods, for which a distinct and consistent groundwater end member may be more difficult to identify.
KW - Distributed temperature sensing
KW - Groundwater-surface-water interaction
KW - Heat tracing
KW - Tracer tests
UR - http://www.scopus.com/inward/record.url?scp=84859637672&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84859637672&partnerID=8YFLogxK
U2 - 10.1002/hyp.8200
DO - 10.1002/hyp.8200
M3 - Article
AN - SCOPUS:84859637672
SN - 0885-6087
VL - 26
SP - 1277
EP - 1290
JO - Hydrological Processes
JF - Hydrological Processes
IS - 9
ER -